2gig PIR1-345 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für Zuhause 2gig PIR1-345 herunter. 2GIG PIR1-345 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
PASSIVE INFRARED MOTION DETECTOR
FCC ID: WDQ-PIR1345
Industry Canada ID: 7794A-PIR1345
INSTALL INSTRUCTIONS
ThePassiveInfraredMotionDetectorisawallmountedunitwithwide
anglemotionprotection.WhensettoHighSensitivityMode,thePassive
InfraredMotionDetector(PIR)hasamaximumrangeof30feetdeepx50
feetwide. ThePIRispetimmuneupto55lbs.
Box Contents
•Detector
•3VLithiumbattery
•3screwsand2dowels
•Bracket
•Flatwallmount
•Cornermount
Programming
Thefollowingstepsdescribegeneralguidelinesforprogramming
(learning)thePIRintotheControlPanel.Scrollbetweenoptionsusingthe
←and→arrows.Movetothepreviousornextpromptbypressingthe↑
and↓arrows.
1 SelectRFsensor#(01to48).AssignthePIRtoanewzone.
2 SelectRFsensortype:
(04)interiorfollower
(10)int
eriorwithdelay
3 SelectRFsensorequipmentcode.Enter0533forthePassiveInfrared
MotionDetector.
4 SelectRFequipmenttype.
(2)moti
on
5 EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitsoftheTXIDthatisfound
outsideoftheboxoronthebackofthedevice.
AutoEntry:WiththepanelinLearninmode,(pressShiftthenLearn)
pressthetamperswitch.ThecorrectTXIDshouldap
pear.Acceptthe
correctTXIDbypressingok.
Remembertopr
essthe↓arrowtocontinuegoingthroughthe
systemconfigurationprompts.
6 SelectRFsensorequipmentage(0to1).
(0)new(
productisnew)
(1)ex
isting(productalreadyexists)
7 SelectRFsensorloopnumber(1to3).
8 SelectRFSensordialerdelay(0to1)
(0)disable
d
(1)ena
bled
9 ConstructRFsensorvoicedescriptor.PressInsertthenpressany
numberbetween002and255toaddaword.Repeatthisforeach
word.Forexample,ifyouwanttonamethisPIRasthe“master
bedroom,pressInsertthenpress140formaster.PressInsertthen
press024forbedroom.
10 SelectRFsensorreports(0to1).
(0)disable
d(PIRdoesnotreporttothecentralstation)
(1)ena
bled(PIRreportstothecentralstation)
11 SelectRFsensorsupervised(0to1)
(0)disable
d(detectordoesnotreportlossofsupervision/lowbattery)
(1)ena
bled(detectorreportslossofsupervision/lowbattery)
12 SelectRFsensorchime(0to13).
(0)disable
d(panelwillNOTchimewhenPIRisactivated)
(113
)enabled(selectsavoiceandchimetosoundonthepanelwhen
thePIRisactivated)
13 Toprogramanothersensorclicknext.
14 Toexitprogramming,clickskipthenendandexit.Uponexit,the
paneltakesseveralsecondstoreboot.
Testing
Beforemountingthedetector,ensurethatthePIRmountinglocation
providesgoodRFcommunicationtothepanel.Toverify,dothefollowing:
1 FromtheInstallerToolbox,selectwalktest.
2 PlacetheamagnetoverthearrowontheleftsideofthePIR,(the
detector’sLEDindicatesthatamagnethasbeendetected)andthen
removethemagnet(amagnetisnotsupplied).
3 PlacethePIRinthelocationthatyouplanonmountingit.
4 MoveintheareathatistobecoveredbythePIRandmakesurethat
theLEDonthePIRflasheseverytimeyoumove.TheLEDflashing
continuesfor1minutesoyoucancheckthePIRbeamcoverage.
NOTE: Thereisa3seconddelaybetweenflashesontheLED.
IMPORTANT: Thefollowingcancauseafalsealarmwhentesting:
•Leavingthecoveroff
•Removingjumpers
PositioningthePIRindirectsunlightorcloseproximitytoaheatingor
anairconditioningduct
5 Exitinstallertoolbox.
Inserting and Replacing Batteries
IfasupervisedPIRbatteryislow,alowbatterynotificationisindicatedon
theControlPanel’ stouchscreen.Ifindicated,replacethebattery
immediately.Useonlytherecommendedreplacementbatteries(See
Specifications).
•Removebackcoverbyunscrewingbottomscrewandpullbackcover
frombottomtotop.Observethepolarityofthebat
tery.SeeFigure2.
WARNING: Improperhandlingoflithiumbatteriesmayresultinheat
generation,explosionorfire,resultinginpersonalinjuries.
Replaceonlywiththesameorequivalenttypeofbatteryas
recommendedbythemanufacturer(seeSpecifications).
Batteriesmustnotberecharged,disassembledordisposedofinfire.
Disposalofusedbatteriesmustbemadeinac
cordancewiththe
wasterecoveryandrecyclingregulationsinyourarea.KeepAway
FromSmallChildren.Ifbatteriesareswallowed,promptlyseek
medicalattention.
CaliforniaOnly:ThisPerchloratewarningappliesonlytoManganese
DioxideLithiumcellssoldordistributedONLYin/California,U.S.A.
PerchlorateMaterialspecialhandlingmayapply.Seedt
sc.ca.gov/
hazardouswaste/perchlorate.
Installing and Mounting
RemovethescrewfromthebottomofthecaseandopenthePIR(see
Figure1).
1 Installthe3VLithiumbatteryfromthebox.
2 Settheleftjumper(PETIMMUNITY)toeither33lbs.(15kg)or55lbs.
(25kg;default).(seeFigure2)
3 Settherightjumper(SENSITIVITY)toeitherLO(default)orHI(see
Figure2).
4 Pressandreleasethetamperswitchtobeginthepowerupprocess.
5 Wait10secondsforthePIRtofullypowerup.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - INSTALL INSTRUCTIONS

PASSIVE INFRARED MOTION DETECTORFCC ID: WDQ-PIR1345Industry Canada ID: 7794A-PIR1345INSTALL INSTRUCTIONSThePassiveInfraredMotionDetectorisawall

Seite 2 - Using the PIR with Pets

Mounting the PIR with the bracket (see Figure 2)1 UseshortPhillipsheadscrewstoscrewpartAintopartB.2 Selecteitherthecornermount(partC)

Kommentare zu diesen Handbüchern